Abhijeet Dharmapurikar authored
We observed that to fully charge a depleted battery with a 500mA source the default safety time of 180 minutes is insufficient. The safety timer kicks in at around 95% and stops charging the battery. Instead of assuming a default of 180 minutes, calculate the charge time required based on battery capacity and the minimum possible charge current. Add a 20 minute buffer period to this calculated safety time. CRs-Fixed: 414619 Change-Id: I08d8d319d096c050ae53d90eeac293c9b1bab2bf Signed-off-by:
Abhijeet Dharmapurikar <adharmap@codeaurora.org>
77b1f6bf